CADDX NX 8 PROGRAMMING PDF

Download the Interlogix Networx (NX4, NX6, NX8, NX8E) Quickstart Guide HERE Programming Code = Master User Code= Program Mode= *8 +. The NX-8E NetworX from Caddx represents a new approach to the design of security systems. The NX-8E is probably the most flexible, durable, and. OFF I_ OFF_I 7 Test Reports Disabled. OFF I_ OFF_I 8 Program, Download & Log Full Disabled. Events to Report Phone 2 Second segment (Toggle On/Off then.

Author: Zulkigor Dagal
Country: Moldova, Republic of
Language: English (Spanish)
Genre: Sex
Published (Last): 16 March 2005
Pages: 221
PDF File Size: 4.96 Mb
ePub File Size: 15.96 Mb
ISBN: 162-3-49482-939-3
Downloads: 17142
Price: Free* [*Free Regsitration Required]
Uploader: Mulkis

Check out our YouTube training videos.

Smart Home, made easy. Please login or register.

Did you miss your activation email? Home Help Search Login Register. The settings below show how to program the NX8-e directly from the alarm lcd panel: Here are the steps and location entries you must make to program the alarm for Vera plugin control of the alarm system: The factory default program code is “” but most alarm companies change the program code and are reluctant to give cxddx out You must get this “program” code to continue or get the alarm company to program progrmming following!

  LEI 11284 DE 2006 PDF

For Locationenter ” “. After entering, for exampleyou are greeted with a series of “Segments” Segment 1, Segment 2 etc Some locations have only one segment and others have several.

Each segment has up to 8 data positions 1 2 3 4 5 6 7 8 which are either prograkming on you see the number displayed on the screen or OFF the individual number is NOT displayed.

The asterisk also takes you from segment to segment. Location Data to be entered: March 30, I had an issue where program,ing panel became disconnected from my Vera unit tends to happen when my lights go off, haven’t figured it out yet and I have to reboot the alarm system and reload Luup engine to fix it.

Caddx NX-8 v1 Program Sheet

Somehow my baud rate was set to for my serial connection on Vera and when I went back through all my settings I noticed that this post indicated my baud rate should be set to option 4 31, There was no corresponding value in Vera for that baud rate so I left it at Took a look this morning as I could not get it to communicate and checked what I had my panel set at and it was indeed 4.

  DEVELOP SUPER POWER MEMORY HARRY LORAYNE PDF

I looked at the book and option 4 is 38, Once I set my baud progrxmming in Vera to match it worked.

Just thought I would make note of this. I don’t think the baud rate matters as long as they match on the panel and vera side.

But is not a valid option according to the documentation in my prorgamming. Since I don’t dabble in this frequently this threw me for a loop so I thought I would post the correct value in case anyone else has this problem.